- Operating temperature: from -45 up to +125°C
- Shrink ratio: 3:1, 4:1
- Minimum shrink temperature: +80°C
- Standard colour: black
- Custom colour: colorless
- Outer shell – self-extinguishing (except a colorless)
Tube type |
Index |
Dimensions [mm] |
Adhesive layer thickness |
Standard length of the spool |
||
shrink ratio: 1:1 |
(black color) |
D |
d |
s |
[mm] – S1 |
[m] |
RC3K 3 / 0,6 |
TRDHL300006002005KC1 |
3,0 |
0,6 |
1,0 |
0,50 |
200 |
RC3K 4,8 / 1,5 |
TRDHL480015001005KC1 |
4,8 |
1,5 |
1,1 |
0,50 |
100 |
RC3K 6 / 2 |
TRDHL600020001005KC1 |
6,0 |
2,0 |
1,2 |
0,50 |
100 |
RC3K 9 / 3 |
TRDHL900030005004KC1 |
9,0 |
3,0 |
1,3 |
0,60 |
50 |
RC3K 12 / 4 |
TRDHL120140002504KC1 |
12,0 |
4,0 |
1,7 |
0,80 |
25 |
RC3K 19 / 6 |
TRDHL190160002504KC1 |
19,0 |
6,0 |
2,0 |
0,80 |
25 |
RC3K 24 / 8 |
TRDHL240180002504KC1 |
24,0 |
8,0 |
2,2 |
1,05 |
25 |
RC3K 30 / 10 |
TRDHL300110011223KC1 |
30,0 |
10,0 |
2,4 |
1,05 |
Cut into 1,22 m |
RC3K 40 / 13 |
TRDHL400113012504KC1 |
40,0 |
13,0 |
2,5 |
1,05 |
25 |
RC3K 50 / 19 |
TRDHL500119011223KC1 |
50,0 |
19,0 |
2,5 |
1,05 |
Cut into 1,22 m |
Tube type |
Index |
Dimensions [mm] |
Adhesive layer thickness |
Standard length of the spool |
||
shrink ratio: 4:1 |
(black color) |
D |
d |
s |
[mm] – S1 |
[m] |
RC4K 4 / 1 |
TRDHL400010001005KC1 |
4 |
1,00 |
1,00 |
0,50 |
100 |
RC4K 6 / 1,27 |
TRDHL600012701005KC1 |
6 |
1,27 |
1,20 |
0,60 |
100 |
RC4K 8 / 1,65 |
TRDHL800016505004KC1 |
8 |
1,65 |
1,55 |
0,75 |
50 |
RC4K 12 / 2,41 |
TRDHL120124102504KC1 |
12 |
2,41 |
1,95 |
1,00 |
25 |
RC4K 16 / 4 |
TRDHL160140002504KC1 |
16 |
4,00 |
2,10 |
1,05 |
25 |
RC4K 18 / 4,45 |
TRDHL180144502504KC1 |
18 |
4,45 |
2,40 |
1,20 |
25 |
RC4K 24 / 6 |
TRDHL240160002504KC1 |
24 |
6,00 |
2,50 |
1,25 |
25 |
RC4K 32 / 8 |
TRDHL320180002504KC1 |
32 |
8,00 |
2,50 |
1,25 |
25 |
RC4K 52/13 |
TRDHL520113011223KC1 |
52 |
13,00 |
2,50 |
1,25 |
Cut into 1,22 m |
Properties |
Test method |
Tubes RC3K / RC4K |
Tensile strength |
ASTM D 2671 |
minimum 10,4 MPa |
Tensile strength after heat ageing (+158°C, 168 h) |
ASTM D 2671 |
pozostaje 70% |
Elongation at rupture |
ASTM D 2671 |
minimum 200% |
Length change after shrinking |
UL 224 |
0 -10% |
Heat shock (+250°C, 4 h) |
ASTM D 2671 |
no cracks |
Cold bend (-30°C, 1 h) |
ASTM D 2671 |
no cracks |
Voltage test AC (2500 V, 60 s) |
ASTM D 2671 |
No breakdowns |
Volume resistivity |
ASTM D 876 |
minimum 1014 Ωcm |
Inflammability test |
SAE-AMS-DTL-23053/5 |
self-extinguishing after 30 s |
Infuence on copper (+158°C, 168 h) |
UL 224 |
no corrosion |