- Operating temperature: -55 up to +200°C (IEC 216)
- The minimum shrink temperature: +150°C
- Standard color: black
- Self-extinguishing
- Produced from modified fluoroelastomer radtiation crosslinked
Tube type |
Index |
Dimensions [mm] |
Standard length |
||
D |
d |
s |
[m] |
||
RFE 3,2 / 1,6 |
TRJHR3200160010050C1 |
3,2 |
1,6 |
0,76 |
50 |
RFE 4,8 / 2,4 |
TRJHR4800240050040C1 |
4,8 |
2,4 |
0,90 |
50 |
RFE 6,4 / 3,2 |
TRJHR6400320010050C1 |
6,4 |
3,2 |
0,90 |
50 |
RFE 9,5 / 4,8 |
TRJHR9500480050040C1 |
9,5 |
4,8 |
0,90 |
50 |
RFE 12,7 |
TRJHR1271640030040C1 |
12,7 |
6,4 |
1,10 |
30 |
RFE 19,1 |
TRJHR1911950030040C1 |
19,1 |
9,5 |
1,30 |
30 |
RFE 25,4 |
TRJHR2541127115040C1 |
25,4 |
12,7 |
1,65 |
30 |
RFE 38,1 |
TRJHR3811191115040C1 |
38,1 |
19,1 |
1,90 |
15 |
Properties |
Test method |
Tube RFE |
Tensile strength |
ASTM D 2671 |
minimum 8,5 MPa |
Tensile strength after ageing |
+250°C, 168 h |
minimum 200% |
Heat shock |
+300°C, 4 h |
no cracks |
Secant modulus |
ASTM D 412 |
maksimum 13,8 MPa |
Dielectric strength |
ASTM D 2671 |
minimum 7,9kV/mm |
Volume resistivity |
ASTM D 876 |
1014Ωcm |
Infuence on copper (+175°C, 16 h) |
SAE-AMS-DTL-23053/13 |
doesn’t corrode |
Flammability |
ASTM D 2671 |
self-extinguishing after 15 s |