Heat shrink thin wall tubes, heat-resistant 125°C – type RCH1

Heat shrink thin wall tubes, heat-resistant 125°C – type RCH1

Application: Universal heat shrinkable tubes applied to perform electrical insulation, technical and moisture protection.
They assume a shape of the object on which they are shrinking down, form a tightly adherent layer of an insulating, anticorrosion and decorative character.

  • Operating temperature: -55 up to +125°C.
  • Shrink ratio: 2:1, 4:1.
  • The minimum shrink temperature: +115°C.
  • Colours: look below
  • Not self-extinguishing, halogen-free
  • UV resistantIn accordance with REACH, RoHS
Tube type Index

Dimensions [mm]

Packing

Spools

shrink ratio: 2:1 (black color)

D

d

s

[pcs 1 m]

[m]

RCH1 1,6 / 0,8 WRJCC1600080010030C1

1,6

0,8

0,45

100

100

RCH1 2,4 / 1,2 WRJCC2400120010030C1

2,4

1,2

0,5

100

100

RCH1 3,2 / 1,6 WRJCC3200160010030C1

3,2

1,6

0,5

100

100

RCH1 4,8 / 2,4 WRJCC4800240010030C1

4,8

2,4

0,5

100

100

RCH1 6,4 / 3,2 WRJCC6400320010030C1

6,4

3,2

0,6

100

100

RCH1 9,5 / 4,8 WRJCC9500480010030C1

9,5

4,8

0,6

100

100

RCH1 12,7 / 6,4 WRJCC1271640010030C1

12,7

6,4

0,6

100

100

RCH1 15,8 / 7,9 WRJCC1581790010030C1

15,8

7,9

0,8

50

100

RCH1 19 / 9,5 WRJCC1901950010030C1

19,0

9,5

0,9

50

100

RCH1 25,4 / 12,7 WRJCC2541127110030C1

25,4

12,7

0,9

50

100

RCH1 31,8 / 15,9 WRJCC3181159110030C1

31,8

15,9

1,0

50

50

RCH1 38 / 19 WRJCC3801190110030C1

38,0

19,0

1,1

50

50

RCH1 51 / 25,5 WRJCC5101255110030C1

51,0

25,5

1,1

40

25

RCH1 76 / 38 WRJCC7601380110030C1

76,0

38,0

2,3

20

25

RCH1 102 / 51 WRJCC1022510110030C1

102,0

51,0

2,0

20

25

Tube type Index

Dimension [mm]

Packing

Spools

shrink ratio 4:1

(black color)

D

d

s

[pcs 1 m]

[m]

RCH1 4 / 1 WRJCC4000100010030C1

4,0

1,0

1,0

100

100

RCH1 8 / 2 WRJCC8000200010030C1

8,0

2,0

1,0

100

100

Standard length 1 meter. Tubes on spools are supplied round or flat up to dimension 12,7/6,4. Tubes on spools of larger dimensions than 12,7/6,4 are supplied flat. Tubes of other colors and length (cut into pieces) are supplied on special request.
Indexes: if you choose pipes with different colors, please replace the last two characters in the index black tubes (C1) on: D1 (red colour), E1 (blue), I1 (green), J1 ( yellow), L1 (mix of colors), K1 (yellow-green), O1 (colorless), A1 (white), P1 (purple), B1 ( brown), H1 (grey).

 

Properties Test method Tubes RCH1S
Operating temperature -55 up to +125°C
Length change after shrinking EN 60684-2

+5 ÷ -10%

Tensile strength, min. EN 60684-2

15MPa

Elongation at rupture, min. EN 60684-2

350%

Heat ageing 168 hours, temperature 158°C EN 60684-2

158°C

Tensile strength after heat ageing, min. EN 60684-2

12MPa

Elongation at rupture after heat ageing, min. EN 60684-2

250%

Heat shock (4 hours, temperature) EN 60684-2

175°C, no dripping,
breaking and wall spreading

Contact with Cu after heat ageing (168 hours, temperature 158°C) EN 60684-2

158°C: 100%

Cu corrosion EN 60684-2

doesn’t corrode

Cold bend; 4 hours EN 60684-2

doesn’t break in temp. -55°C

Flammability EN 60684-2

inflammable

Water absorptivity, max ISO 62

0,1%

Dielectric resistance, min. EN 60684-2; IEC 60243-1

16kV/mm

Volume resistivity, min. EN 60684-2; IEC 60093

1012Ωm

Examples of applications of heat shrink tubes